Test Variables
- Resistance at the beginning of the test [Ω]: 15.39
- Ambient temperature [°C]: 24
- Coefficient of temperature: 0.0038684719535783366
- Uncertainty of initial time [s]: 1
- Uncertainty of acquisition time [s]: 0.001
- Uncertainty of resistance measurement [Ω]: 0.001
- Uncertainty of ambient temperature measurement [°C]: 0.1
- Number of Monte Carlo simulations: 200
Model comparison
Mean and Std values
| Model Type |
Degree |
SSE [Ω²] |
Resistance [Ω] |
Resistance estimation uncertainty [Ω] |
Temperature [°C] |
Temperature uncertainty [°C] |
| poly |
1 |
14866 ± 236.07 |
19.423 ± 0.024504 |
0.015175 ± 0.00052348 |
91.737 ± 0.41158 |
0.27464 ± 0.0081638 |
| poly |
2 |
157.45 ± 25.042 |
19.517 ± 0.035012 |
0.002908 ± 0.00034856 |
93.315 ± 0.58808 |
0.11343 ± 0.0025658 |
| poly |
3 |
53.515 ± 13.063 |
19.53 ± 0.037557 |
0.0030395 ± 0.00065385 |
93.54 ± 0.63083 |
0.11469 ± 0.0051557 |
| poly |
4 |
41.842 ± 11.408 |
19.538 ± 0.039852 |
0.0048877 ± 0.0014578 |
93.668 ± 0.66938 |
0.13241 ± 0.016156 |
| exp |
0 |
59.149 ± 14.103 |
19.528 ± 0.037224 |
0.049997 ± 0.0021766 |
93.502 ± 0.62524 |
0.84599 ± 0.036292 |